Motion detectorsRC
RC 230 KNX
Item number EM10015472The RC outdoor motion detectors are suitable for all common applications on building façades and projections due to the wide range of setting and installation options. A special bracket also enables trouble-free wall or ceiling mounting on inner and outer corners. 360° creep protection ensures unbroken coverage — and therefore maximum safety.
Shortfacts
| Installation type | Surface mounting |
| Installation position | Ceiling / Wall |
| Protection type | IP54 |
| Dimensions | length 135 mm x width 78 mm x Height/Depth 105 mm |
| Detection angle | 230° (2 x 115° separately adjustable) and 360° anti-creep protection |
| Detection range diagonally | Ø 40 m |
| Field of detection | up to 804 m² |
| Light measurement | mixed light |
| Level of brightness | 2 - 1000 lx |
| Warranty | 5 years |
Technical data
| General | |
|---|---|
| Special product features | Anti-creep protection , One-hand plug-in base , Twilight switch (1 item) , Motion direction detection (3 item) , Light-dependent motion detection , Brightness detection via the object |
| Conformity | CE , RoHS , WEEE |
| Mounting | |
|---|---|
| Installation type | Surface mounting |
| Installation position | Ceiling / Wall |
| Connection | 2,5 mm² / 1,5 mm² |
| Housing | |
|---|---|
| Dimensions | length 135 mm x width 78 mm x Height/Depth 105 mm |
| Weight | 310 g |
| Material | UV-stabilised polycarbonate |
| Protection type | IP54 |
| Permissible ambient temperature | -25 °C...+55 °C |
| Relative humidity | 5 - 95 %, non-condensing |
| Colour | white, similar to RAL 9010 |
| Electrical version | |
|---|---|
| Protection class | III |
| Nominal voltage | 29 - 31 V |
| Power consumption | 6 mA |
| Sensors | |
|---|---|
| Detection angle | 230° (2 x 115° separately adjustable) and 360° anti-creep protection |
| Detection range diagonally | Ø 40 m |
| Detection range head-on | Ø 8 m |
| Field of detection | up to 804 m² |
| Recommended installation height | 2.5 m |
| Max. mounting height | 4 m |
| Level of brightness | 2 - 1000 lx |
| Slave input | Yes, unit can be configured as a master or slave device |
| Fully automatic | yes |
| Semi-automatic | yes |
| constant lighting control | 1 |
| Switching delay from "dark to light" [s] | 300 s |
| Switching delay from "light to dark" [s] | 30 s |
| Control | |
|---|---|
| Channel 1 | Lighting |
| Interface | Switching/Dimming |
| Contact | Bus system |
| Switch-off delay time | disabled/30 seconds to 30 min |
| Orientation light | disabled/10 - 50 %, 2 values can be selected |
| Switch-off delay time, orientation light | only in controlling modus: continuous lighting/1 min - 250 min |
| Channel 2 | HVAC |
| Output | Switching |
| Contact | Bus system |
| Turn-on delay | disabled/2 min - 30 min |
| Switch-off delay channel 2 | 10 sec.–1 hour |
| Bus voltage | 29-31 V = (KNX) |
| Master/slave function | 1 |
| constant lighting control | 1 |
| Presence simulation | 1 |
| Manual override | yes |
Downloads
| GENERAL | ||
|---|---|---|
| Data sheet | ||
| Installation | ||
|---|---|---|
| Short instruction | ||
| Operating instructions | ||
| KNX application / software | ZIP | |
| Tender specifications | ||
|---|---|---|
| Invitation to tender text | RTF | |